Ultraflex Liquid Tight Flexible Conduit
Nassau Cable is a trusted distributor of industrial, commercial wire and cable, offering quality and best price. We ship the products worldwide.
Ultraflex Liquid Tight Flexible Conduit
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket , Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
3/8 Trade Ultraflex Liquid Tight Flexible Conduit 160-012
Allowable Ampacity for 3/8 Trade Ultraflex Liquid Tight Flexible Conduit 160-012: 100 Amps
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket , Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
Specification:
• Trade Size: 3/8 Inches
• Coil Length: 100 FT
• Weight: 0.0525 lbs/ft
• Internal Diameter Min: 0.484 Inches
• Internal Diameter Max: 0.504 Inches
• External Diameter Min: 0.695 Inches
• External Diameter Max: 0.705 Inches
• Bend Radius: 0.49 Inches
• 100' Coil Code: 160-012
1/2 Trade Ultraflex Liquid Tight Flexible Conduit 160-016
Allowable Ampacity for 1/2 Trade Ultraflex Liquid Tight Flexible Conduit 160-016: 100 Amps
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket, 160-016, Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
Specification:
• Trade Size: 1/2
• Coil Length: 100 FT
• Weight: 0.084 lbs/ft
• Internal Diameter Min: 0.622 Inches
• Internal Diameter Max: 0.642 Inches
• External Diameter Min: 0.825 Inches
• External Diameter Max: 0.835 Inches
• Bend Radius: 0.63 Inch
• Part Number: 160-016
3/4 Trade Ultraflex Liquid Tight Flexible Conduit 160-021
Allowable Ampacity for 3/4 Trade Ultraflex Liquid Tight Flexible Conduit 160-021: 100 Amps
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket, 160-021, Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
Specification:
• Trade Size: 3/4
• Coil Length: 100 FT
• Weight: 0.1155 lbs/ft
• Internal Diameter Min: 0.820 Inches
• Internal Diameter Max: 0.840 Inches
• External Diameter Min: 1.035 Inches
• External Diameter Max: 1.045 Inches
• Bend Radius: 0.83 Inch
• Part Number: 160-021
1 Trade Ultraflex Liquid Tight Flexible Conduit 160-026
Allowable Ampacity for 1 Trade Ultraflex Liquid Tight Flexible Conduit 160-026: 100 Amps
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket, 160-026, Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
Specification:
• Trade Size: 1
• Coil Length: 100 FT
• Weight: 0.1680 lbs/ft
• Internal Diameter Min: 1.041 Inches
• Internal Diameter Max: 1.066 Inches
• External Diameter Min: 1.297 Inches
• External Diameter Max: 1.308 Inches
• Bend Radius: 1.10 Inch
• Part Number: 160-026
1-1/4 Trade Ultraflex Liquid Tight Flexible Conduit 160-035
Allowable Ampacity for 1-1/4 Trade Ultraflex Liquid Tight Flexible Conduit 160-035: 100 Amps
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket, 160-035, Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
Specification:
• Trade Size: 1-1/4
• Coil Length: 100 FT
• Weight: 0.2205 lbs/ft
• Internal Diameter Min: 1.380 Inches
• Internal Diameter Max: 1.410 Inches
• External Diameter Min: 1.640 Inches
• External Diameter Max: 1.650 Inches
• Bend Radius: 1.40 Inch
• Part Number: 160-035
2 Trade Ultraflex Liquid Tight Flexible Conduit 160-051
Allowable Ampacity for 2 Trade Ultraflex Liquid Tight Flexible Conduit 160-051: 100 Amps
Applications:
• Recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.
• Non-UL liquidtight raceway
Also Known As:
Type Non-UL, Ultraflex Flexible Conduit, Type SJT Conduit, Liquid Tight Conduit, PVC Jacket, 160-051, Flexible Conduit.
Description:
Non-UL liquidtight Raceway Component, Extra-Flexible Non-Metallic Mechanical ProtectionTubing. Corrugated flame resistant PVC with integral reinforcing member. Non-conductive raceway – black.
Construction:
LIQUID-TUFF™ Liquidtight ULTRAFLEX™ MECHANICAL PROTECTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.
Temperature Rating:
• 60°C Dry
• 60°C Wet and oily
References & Ratings:
• Recognized component Liquidtight Mechanical Protection
• Tubing under UL File Number E79977
• UL1696 Standard for Non-Metallic Mechanical Protection Tubing
• CSA File LL69271
• CSA C22.2 No. 227.3
Grounding:
Where applicable a separate grounding conductor is required for all trade sizes.
Markings:
The product marking is contained on the outer carton.
Performance Tests:
The completed LIQUID-TUFF™ Liquidtight ULTRAFLEX™ TUBING and CONDUIT shall meet the performance requirements outlined below.
Performance Requirements:
• Heat Aging Test
• Cold Bend Test
• Heat Shock Test
• Crush Test
• Impact Test
• Oil Spray Test
Standards:
• CSA C22.3 No. 227.3
• UL1696
• Non-metallic Mechanical Protection Tubing
File:
• UL E79977
• CSA 69271
Specification:
• Trade Size: 2
• Coil Length: 100 FT
• Weight: 0.3465 lbs/ft
• Internal Diameter Min: 2.020 Inches
• Internal Diameter Max: 2.045 Inches
• External Diameter Min: 2.352 Inches
• External Diameter Max: 2.363 Inches
• Bend Radius: 2.04 Inch
• Part Number: 160-051
![Ultraflex Liquid Tight Flexible Conduit](https://usp.imgix.net/catalog/images/products/tubing/400/54954p.jpg?w=376&dpr=2&fit=max&auto=format)
![Ultraflex Liquid Tight Flexible Conduit](https://images.thdstatic.com/productImages/07d2b3fd-991f-467d-afbe-209ac501e9d2/svn/southwire-conduit-59714701-64_1000.jpg)
![Ultraflex Liquid Tight Flexible Conduit](https://i5.walmartimages.com/asr/59c8cde0-f409-4b64-a78f-6ae9d8714936.71cd33b4e5b65499cfb0b29ed0c6d99a.jpeg?odnHeight=320&odnWidth=320&odnBg=FFFFFF)
![Ultraflex Liquid Tight Flexible Conduit](https://sp-ao.shortpixel.ai/client/to_auto,q_lossless,ret_img,w_850,h_638/https://ultraflexpower.com/wp-content/uploads/2017/04/Stay-Silv-white-brazing-flux-4-1.jpg)
![Ultraflex Liquid Tight Flexible Conduit](https://i.ebayimg.com/images/g/XvIAAOSwt0FZB9hD/s-l1200.webp)
![Ultraflex Liquid Tight Flexible Conduit](https://nassaunationalcable.com/cdn/shop/files/Bekaert-cable-and-hose-braiding-wire_3_x215.png?v=1674368890)
![Ultraflex Liquid Tight Flexible Conduit](https://solarbuildermag.com/wp-content/uploads/2015/07/Flexicon-DSC_0316-reduced-cut-2.jpg)
![Ultraflex Liquid Tight Flexible Conduit](https://rexel-cdn.com/Products/Product.jpg?i=560DF0D8-E866-41F1-9CF4-E88A3AD26DBA&f=300-sq)
![Ultraflex Liquid Tight Flexible Conduit](https://i.pinimg.com/474x/3e/b5/cb/3eb5cb8de924ff98f70d137cd2f1ce61.jpg)
![Ultraflex Liquid Tight Flexible Conduit](http://shop.fibercommand.com/cdn/shop/files/labfiber-non-magnetic-fiber-optic-cable-for-medical-labs-by-provideoinstruments-1.jpg?v=1709672196)
![Ultraflex Liquid Tight Flexible Conduit](https://nassaunationalcable.com/cdn/shop/products/0000000_16f0dfa6-ecc5-4f4d-be25-0c6dd57a1f6a_175x175@2x.jpg?v=1643203562)
![Ultraflex Liquid Tight Flexible Conduit](https://m.media-amazon.com/images/I/61iSMAxVWKL._AC_UF350,350_QL80_.jpg)
![Ultraflex Liquid Tight Flexible Conduit](https://flexiblewiringconduits.anacondasealtite.com/Asset/a1026.jpg)